Coarse Straining

Upstream protection and bulk separation

Cartridge Filtration

Precision fine and depth filtration

Membrane Technologies

Micro, ultra, nano and reverse osmosis

Pre-Treatment

Conditioning ahead of the process

Purification

Reverse osmosis and demineralization

Polishing and Service

High purity finishing and on-site support

Description

Capture, clean, expel: how Ronningen-Petter systems from Eaton work
Every process is unique – that’s why we offer several backwashing/tubular systems in several configurations.

Our flagship tubular systems. During backwash, a single tube is taken off-line from the process flow via a three-way valve. Once an element is clean, it is returned to service and the next element may be cleaned. The remaining elements in the filter remain operational throughout this cycle. F-Series and AFC-Series multiplex units consist of 2-20 individual tubes valved in parallel to common inlet, outlet, and drain headers. AFC-Series units are also available in economical single and duo-tube configurations, which must be removed from service for manual cleaning.

AFC-Series – high-pressure capability and modular flexibility
When your application demands high-pressure operation – up to 1,000 psi (69 bar) – and scaleable flexibility, the Ronningen-Petter AFC-Series is optimal. AFC-Series systems are available in single-, duo-, and multiplex configurations to meet your application and business demands.

Duo Filters
Ronningen-Petter AFC-Series duo filters consist of two single filter units connected to a pair of 3-way valves for continuous service during cleaning or maintenance. For this reason, duo filters are typically rated at the same capacity as a single. But, for intermittent service applications, the valves can be positioned so that both units operate simultaneously.

Specifications

Body Diameter
2.875 in / 73 mm
Body Inlet / Outlet Size
1 in / 25.4 mm
Element Styles Available
2 in (50.8mm) Diameter Single
High Pressure Rating
17.2 bar / 250 psi
Screen Length
18, 12 in / 457.2, 304.8 mm
Standard Drain Size
0.75 in / 19 mm
Standard Pressure Rating
10.3 bar / 150 psi
Strainer Model
AFC 1100 Duo Unit
Strate-Thru Drain Size
0.5 in / 12.7 mm
Total Unit Weight
36.3, 40.8 kg / 80, 90 lb
Total Volumetric Capacity
1, 0.8 gal / 3.8, 3.0 L
Total Volumetric Capacity – model #
1112, 1118

Note

350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi available in strate-thru design only.
All high pressure units incorporate 2-way ball valves.

Consult factory for optional additional drain sizes.

Cake Formation Increases Operational Efficiency

While the filtration media provides some of the filtration action, collected contaminants actually further increase efficiency. We call this phenomenon “cake formation.” The collected solids (or “cake”) trap additional contaminants. The key to making this principle work is timely cleaning – too soon and you lose the benefit, too late and the system flow becomes hindered.

Ronningen-Petter systems come factory pre-set to backwash when the differential pressure from inlet to outlet reaches 15 psi (1 bar) – typically the optimum time to initiate backwashing, although this is adjustable.

Line Specifications

Filter Media Material
Fabric: 230 – 1 micron, Slotted: 1,600 – 25 microns, Wire mesh: 1,650 – 2 microns

Request a Quote

This part number is already on the request. Tell us how many you need and our specialists will come back to you.

Phone Number
Filled in from the part you choose. Change it if your request is about a different part.