AFC-Series Backwashing/Tubular Filter Systems

Cake Formation Increases Operational Efficiency

While the filtration media provides some of the filtration action, collected contaminants actually further increase efficiency. We call this phenomenon “cake formation.” The collected solids (or “cake”) trap additional contaminants. The key to making this principle work is timely cleaning – too soon and you lose the benefit, too late and the system flow becomes hindered.

Ronningen-Petter systems come factory pre-set to backwash when the differential pressure from inlet to outlet reaches 15 psi (1 bar) – typically the optimum time to initiate backwashing, although this is adjustable.

Specifications

Filter Media Material
Fabric: 230 – 1 micron, Slotted: 1,600 – 25 microns, Wire mesh: 1,650 – 2 microns

Part Numbers

11 parts available

Part NumberStrainer ModelBody Inlet / Outlet Size (in / mm)Inlet / Outlet Header Size (in / mm)Screen Length (in / mm)Element Styles AvailableBody Diameter (in / mm)Standard Pressure Rating (bar / psi)High Pressure Rating (bar / psi)Air Requirement (Automated Units) @ 5 cfm, for Sequencing (bar / psi)Electrical Requirement (Automated Units)Internal and External Backwashing ConfigurationsTotal Volumetric Capacity – model #Total Volumetric Capacity (gal / L)Single Unit Weight (kg / lb)Standard Drain Size (in / mm)Strate-Thru Drain Size (in / mm)NoteTotal Unit Weight (kg / lb)
item-5709AFC 1100 Multiplex Unit1 in / 25.4 mm3, 4 in / 76.2, 101.8 mm18 in / 457.2 mm2 in (50.8mm) Diameter Style2.875 in / 73 mm10.3 bar / 150 psi17.2 bar / 250 psi4.1 – 8.3 bar / 60 – 120 psi110/220 V, 50/60 Hz, Single PhaseRonningen-Petter AFC-Series tubular multiplex systems are…–––––––
item-5710AFC 2200 Multiplex High-Pressure Unit2 in / 50.8 mm3, 4, 6, 8, 10, 12 in / 76.2, 101.8, 152.4, 203.2, 254, 304.8 mm36 in / 914.4 mm3.25 in (82.3mm) Diameter Single, Tri-cluster, Accuflux – 74.25 in / 114.3 mm–101.3 bar / 1000 psi4.1 – 8.3 bar / 60 – 120 psi110/220 V, 50/60 Hz, Single PhaseRonningen-Petter AFC-Series tubular multiplex systems are…–––––––
item-5711AFC 3300 Multiplex Unit3 in / 76.2 mm3, 4, 6, 8, 10, 12 in / 76.2, 101.8, 152.4, 203.2, 254, 304.8 mm36 in / 914.4 mm3.25 in (82.3mm) Diameter Single, Tri-cluster, Accuflux – 74.25 in / 114.3 mm10.3 bar / 150 psi–4.1 – 8.3 bar / 60 – 120 psi110/220 V, 50/60 Hz, Single PhaseRonningen-Petter AFC-Series tubular multiplex systems are…–––––––
item-5712AFC 1100 Single Unit1 in / 25.4 mm–18, 12 in / 457.2, 304.8 mm2 in (50.8mm) Diameter Single2.875 in / 73 mm10.3 bar / 150 psi17.2 bar / 250 psi–––1112, 11180.4, 0.5 gal / 1.5, 1.9 L18, 8.2 kg / 15, 6.8 lb0.75 in / 19 mm0.5 in / 12.7 mm––
item-5713AFC 1500 Single Unit1.5 in / 38.1 mm–36, 24 in / 914.4, 381 mm2.25 in (57.1mm) Diameter Single3.5 in / 88.9 mm10.3 bar / 150 psi17.2 bar / 250 psi–––1524, 15361, 1.4 gal / 3.8, 5.3 L30, 13.6 kg / 25, 11.3 lb0.75 in / 19 mm0.5 in / 12.7 mm––
item-5714AFC 2200 Single Unit2 in / 50.8 mm–18, 36 in / 457.2, 914.4 mm3.25 in (82.8mm) Diameter Single, Tri-Cluster, Accuflux – 74.5 in / 114.3 mm10.3 bar / 150 psi17.2, 101.3 bar / 250, 1000 psi–––2218, 22361.3, 2.4 gal / 4.9, 9.1 L40, 18.1 kg / 35, 15.9 lb1.25 in / 31.75 mm0.5 in / 12.7 mm––
item-5715AFC 3300 Single Unit3 in / 76.2 mm–18, 36 in / 457.2, 914.4 mm3.25 in (82.8mm) Diameter Single, Tri-Cluster, Accuflux – 74.5 in / 114.3 mm10.3 bar / 150 psi––––3318, 33361.3, 2.4 gal / 4.9, 9.1 L45, 20.4 kg / 40, 18.1 lb–0.5 in / 12.7 mmAvailable in Strate-Thru design only.–
item-5716AFC 1100 Duo Unit1 in / 25.4 mm–18, 12 in / 457.2, 304.8 mm2 in (50.8mm) Diameter Single2.875 in / 73 mm10.3 bar / 150 psi17.2 bar / 250 psi–––1112, 11181, 0.8 gal / 3.8, 3.0 L–0.75 in / 19 mm0.5 in / 12.7 mm350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi…36.3, 40.8 kg / 80, 90 lb
item-5717AFC 1500 Duo Unit1.5 in / 38.1 mm–36, 24 in / 914.4, 381 mm2.25 in (57.1mm) Diameter Single3.5 in / 88.9 mm10.3 bar / 150 psi17.2 bar / 250 psi–––1524, 15362.0, 2.8 gal / 7.6, 10.6 L–0.75 in / 19 mm0.5 in / 12.7 mm350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi…49.9, 56.7 kg / 110, 125 lb
item-5718AFC 2200 Duo Unit2 in / 50.8 mm–18, 36 in / 457.2, 914.4 mm3.25 in (82.8mm) Diameter Single, Tri-Cluster, Accuflux – 74.5 in / 114.3 mm10.3 bar / 150 psi17.2, 101.3, 24.1, 51.7 bar / 250, 1000, 350, 740 psi–––2218, 22362.6, 4.8 gal / 9.8, 18.2 L–1.25 in / 31.75 mm0.5 in / 12.7 mm350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi…63.5, 72.6 kg / 140, 160 lb
item-5719AFC 3300 Duo Unit3 in / 76.2 mm–18, 36 in / 457.2, 914.4 mm3.25 in (82.8mm) Diameter Single, Tri-Cluster, Accuflux – 74.5 in / 114.3 mm10.3 bar / 150 psi––––3318, 33362.6, 4.8 gal / 9.8, 18.2 L––0.5 in / 12.7 mmAvailable in strate-thru only.350 (24.1 bar), 740 (51.7…81.6, 136 kg / 180, 300 lb

Request a Quote

Select up to five part numbers in the table above, or tell us what you need and our specialists will help you choose.

This part number is already on the request. Tell us how many you need and our specialists will come back to you.

Phone Number
Filled in from the part you choose. Change it if your request is about a different part.
Quantities, timelines, or anything else that would help us quote accurately.