AG8040F-400,WET HR
Part of AG HR Series High Rejection Brackish Water RO Elements


AG HR Brackish Water Elements are selected when high rejection and operating pressures as low as 200 psi (1,379 kPa) are desired.
Literature
Specifications
- Active Area
- 400 ft² / 37.2 m²
- Average NaCl Rejection
- 99.7 %
- Average Permeate Flow
- 38.6 m³/day / 10200 gpd
- Minimum NaCl Rejection
- 99.2 %
- Outer Wrap
- Fiberglass
- Part Number
- 3040994
Note
Trademark of General Electric Company; may be registered in one or more countries.
Note
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating pressure, 77°F, pH7 and 15% recovery.
Line Specifications
- Average NaCl Rejection
- 99.7 %
- Chlorine Tolerance
- 1,000+ ppm-hours, Dechlorination Recommended
- Clean-In-Place (CIP) pH Range
- 2.0 – 11.5
- Continuous Operation pH Range
- 4.0 – 11.0
- Feedwater
- NTU < 1, SDI < 5
- Maximum Clean-In-Place (CIP) Temperature
- 50 °C / 122 °F
- Maximum Continuous Operation Temperature
- 50 °C / 122 °F
- Maximum Operating Pressure
- 4137 kPa / 600 psi
- Maximum Pressure Drop Over an Element
- 83 kPa / 12 psi
- Maximum Pressure Drop Per Housing
- 345 kPa / 50 psi
- Membrane
- Thin-Film Membrane (TFM™)
- Minimum NaCl Rejection
- 99.2 %
- Optimum Rejection pH Range
- 7.0 – 7.5
- Outer Wrap
- Fiberglass
- Typical Operating Flux
- 10 – 20 GFD / 15 – 35 LMH
- Typical Operating Pressure
- 1380 kPa / 200 psi
See more parts in AG HR Series High Rejection Brackish Water RO Elements
Request a Quote
This part number is already on the request. Tell us how many you need and our specialists will come back to you.