High Surface Area Pleated Micro-Fiberglass Cartridges for Critical Processes

Specifications

Absolute Micron Rating
2 µm
Cartridge Style
DOE/Internal 120 Ring
Nominal Length
102 cm / 40 in
Series
Standard

Note

Viton and PTFE are registered trademarks of E.I. duPont de Nemours and Company. ACCU-CLEAR and The Clear Advantage are trademarks of Clarcor, Inc.

Applications

  • Chemical Processing
  • Food and Beverage Processing
  • Membrane Pre-filtration
  • Paints, Coatings, and Inks
  • Solvents
  • Pharmaceuticals
  • Wine Clarification
  • Sterile Air Filtration

Benefits

  • High surface area filter cartridges constructed of pleated micro-fiberglass media provide absolute particle retention and long on-stream life cycles.
  • Absolute removal ratings available from 0.6 to 40 µm.
  • The filter medium with controlled pore sizes and stringent quality control standards guarantee a uniform matrix for effective, consistent filtration performance.
  • Materials of construction provide wide chemical compatibility in most liquid and gas applications.
  • All cartridges are constructed and assembled in a clean room environment to ensure minimal particle contamination.
  • High strength, polypropylene components and advanced thermal bonding techniques ensure cartridge integrity under severe operating conditions.
  • No adhesives, binders, lubricants, or coatings are used in the manufacturing process to ensure the lowest levels of leachables or extractables.
  • Pharmaceutical grade offers 100% lot traceability.

Line Specifications

Cage Material
Polypropylene
Cartridge Media Type
Micro Fiberglass Filter Media
Center Core Material
Polypropylene
Differential Pressure @ 140°F (60°C)
2.04 bar / 30 psid
Differential Pressure @ 77° F (25° C)
4.08 bar / 60 psid
End Caps Material
Polypropylene
Gasket/O-Ring Material
Buna-N, EPR, PTFE Gasket, PTFE/Viton, Silicone, Viton
Media Material
Borosilicate Micro fiberglass with Acrylic Binder
Nominal Outside Diameter
6.8 cm / 2.7 in
Sterilization
ACCU-CLEAR cartridges may be autoclaved for 30 minutes at 121° C under no end loading conditions.
Support Material
Polyester
Toxicity
ACCU-CLEAR Series filter media comply with USP XXII Standards for Class VI-121 Plastics.
Utilization
Non-Steam Sterilizable, Steam Sterilizable